Here's how LINK.SPRINGER.COM makes money* and how much!

*Please read our disclaimer before using our estimates.
Loading...

LINK . SPRINGER . COM {}

  1. Analyzed Page
  2. Matching Content Categories
  3. CMS
  4. Monthly Traffic Estimate
  5. How Does Link.springer.com Make Money
  6. Keywords
  7. Topics
  8. Questions
  9. Schema
  10. External Links
  11. Analytics And Tracking
  12. Libraries
  13. CDN Services

We are analyzing https://link.springer.com/article/10.1007/s10278-012-9458-6.

Title:
Accuracy and Reliability of Length Measurements on Three-Dimensional Computed Tomography Using Open-Source OsiriX Software | Journal of Imaging Informatics in Medicine
Description:
There is a growing interest in three-dimensional computed tomography (3D-CT) as a research tool for the study of bone, joint anatomy, and kinematics. However, when CT data are processed and handled manually using image processing programs to yield 3D image and coordinate value, systematic and random errors should be validated. We evaluated the accuracy and reliability of length measurement on CT with OsiriX software. 3D-CT scans were made of 14 frozen pig knees with five transosseous holes in the metaphyseal portion of femur. The lengths between tunnel orifices were measured using Mitutoyo Digimatic digital calipers to establish the gold standard, and with the OsiriX program in 3D multi-planar reformatting mode for comparison. All measurements were recorded by a principal (replicate 1, trial 1) and a secondary observer (replicate 2, trial 1) and were repeated once by each observer (trial 2). The mean differences between OsiriX and real measurements were less than 0.1 mm in both replicates, and maximum differences were less than 0.3 mm. There were no significant differences between the replicates and real measurements (p = 0.544 and 0.622 for replicates 1 and 2, respectively). The intraclass correlation coefficients (ICC) were very high between trials and between replicates (ICC = 0.998 and 0.999, respectively). For kinematic analysis of the knees, length measurements on 3D-CT using OsiriX program can be used as alternatives to real measurements with less than 0.3-mm accuracy and very high reliability.
Website Age:
28 years and 1 months (reg. 1997-05-29).

Matching Content Categories {📚}

  • Education
  • Photography
  • Virtual Reality

Content Management System {📝}

What CMS is link.springer.com built with?

Custom-built

No common CMS systems were detected on Link.springer.com, and no known web development framework was identified.

Traffic Estimate {📈}

What is the average monthly size of link.springer.com audience?

🌠 Phenomenal Traffic: 5M - 10M visitors per month


Based on our best estimate, this website will receive around 7,734,772 visitors per month in the current month.

check SE Ranking
check Ahrefs
check Similarweb
check Ubersuggest
check Semrush

How Does Link.springer.com Make Money? {💸}

We can't see how the site brings in money.

While profit motivates many websites, others exist to inspire, entertain, or provide valuable resources. Websites have a variety of goals. And this might be one of them. Link.springer.com might be plotting its profit, but the way they're doing it isn't detectable yet.

Keywords {🔍}

article, pubmed, google, scholar, tomography, computed, knee, ligament, surg, osirix, reliability, measurements, threedimensional, cruciate, research, imaging, access, sports, traumatol, arthrosc, analysis, accuracy, tunnel, dimensional, anterior, reconstruction, privacy, cookies, content, journal, length, software, lee, bone, image, data, publish, search, opensource, kim, dct, joint, program, differences, replicates, open, cas, notch, korea, information,

Topics {✒️}

month download article/chapter voxel size-based inaccuracies open-source software osirix open-source osirix software posterior cruciate ligament han-jun lee jae-sung lee mr/ct image fusion open-source software related subjects dimensional computed tomography dimensional computed tomography full article pdf fibular collateral ligament privacy choices/manage cookies bone joint surg nonanatomic tunnel position computed tomography evaluation ligament tensile behavior 2-dimensional notch width ho-joong jung double femoral tunnels improved image management yield 3d image inter-operator reliability national research foundation digital imaging aims dimensional preoperative planning 3-dimensional notch volume dimensional notch volume avoiding tunnel collisions european economic area image processing programs ann biomed eng assessing cortical thickness multidimensional dicom images minimally invasive pancreatectomy chung-ang university computed tomography thin bone structures conditions privacy policy article kim intercondylar roof impingement check access instant access accepting optional cookies 3d-ct scans article journal length measurement journal finder publish

Questions {❓}

  • Taketomi S, Nakagawa T, Takeda H, et al: Anatomical placement of double femoral tunnels in anterior cruciate ligament reconstruction: anteromedial tunnel first or posterolateral tunnel first?

Schema {🗺️}

WebPage:
      mainEntity:
         headline:Accuracy and Reliability of Length Measurements on Three-Dimensional Computed Tomography Using Open-Source OsiriX Software
         description:There is a growing interest in three-dimensional computed tomography (3D-CT) as a research tool for the study of bone, joint anatomy, and kinematics. However, when CT data are processed and handled manually using image processing programs to yield 3D image and coordinate value, systematic and random errors should be validated. We evaluated the accuracy and reliability of length measurement on CT with OsiriX software. 3D-CT scans were made of 14 frozen pig knees with five transosseous holes in the metaphyseal portion of femur. The lengths between tunnel orifices were measured using Mitutoyo Digimatic digital calipers to establish the gold standard, and with the OsiriX program in 3D multi-planar reformatting mode for comparison. All measurements were recorded by a principal (replicate 1, trial 1) and a secondary observer (replicate 2, trial 1) and were repeated once by each observer (trial 2). The mean differences between OsiriX and real measurements were less than 0.1 mm in both replicates, and maximum differences were less than 0.3 mm. There were no significant differences between the replicates and real measurements (p = 0.544 and 0.622 for replicates 1 and 2, respectively). The intraclass correlation coefficients (ICC) were very high between trials and between replicates (ICC = 0.998 and 0.999, respectively). For kinematic analysis of the knees, length measurements on 3D-CT using OsiriX program can be used as alternatives to real measurements with less than 0.3-mm accuracy and very high reliability.
         datePublished:2012-01-20T00:00:00Z
         dateModified:2012-01-20T00:00:00Z
         pageStart:486
         pageEnd:491
         sameAs:https://doi.org/10.1007/s10278-012-9458-6
         keywords:
            Computed tomography
            Accuracy
            Reliability
            Length
            OsiriX
            Imaging / Radiology
         image:
         isPartOf:
            name:Journal of Digital Imaging
            issn:
               1618-727X
               0897-1889
            volumeNumber:25
            type:
               Periodical
               PublicationVolume
         publisher:
            name:Springer-Verlag
            logo:
               url:https://www.springernature.com/app-sn/public/images/logo-springernature.png
               type:ImageObject
            type:Organization
         author:
               name:Gihyeon Kim
               affiliation:
                     name:Chung-Ang University
                     address:
                        name:Department of Radiology, College of Medicine, Chung-Ang University, Seoul, South Korea
                        type:PostalAddress
                     type:Organization
               type:Person
               name:Ho-Joong Jung
               affiliation:
                     name:Chung-Ang University
                     address:
                        name:Department of Orthopedic Surgery, College of Medicine, Chung-Ang University, Dongjak-ku, South Korea
                        type:PostalAddress
                     type:Organization
               email:[email protected]
               type:Person
               name:Han-Jun Lee
               affiliation:
                     name:Chung-Ang University
                     address:
                        name:Department of Orthopedic Surgery, College of Medicine, Chung-Ang University, Dongjak-ku, South Korea
                        type:PostalAddress
                     type:Organization
               type:Person
               name:Jae-Sung Lee
               affiliation:
                     name:Chung-Ang University
                     address:
                        name:Department of Orthopedic Surgery, College of Medicine, Chung-Ang University, Dongjak-ku, South Korea
                        type:PostalAddress
                     type:Organization
               type:Person
               name:Seungbum Koo
               affiliation:
                     name:Chung-Ang University
                     address:
                        name:School of Mechanical Engineering, Chung-Ang University, Seoul, South Korea
                        type:PostalAddress
                     type:Organization
               type:Person
               name:Seung-Hwan Chang
               affiliation:
                     name:Chung-Ang University
                     address:
                        name:School of Mechanical Engineering, Chung-Ang University, Seoul, South Korea
                        type:PostalAddress
                     type:Organization
               type:Person
         isAccessibleForFree:
         hasPart:
            isAccessibleForFree:
            cssSelector:.main-content
            type:WebPageElement
         type:ScholarlyArticle
      context:https://schema.org
ScholarlyArticle:
      headline:Accuracy and Reliability of Length Measurements on Three-Dimensional Computed Tomography Using Open-Source OsiriX Software
      description:There is a growing interest in three-dimensional computed tomography (3D-CT) as a research tool for the study of bone, joint anatomy, and kinematics. However, when CT data are processed and handled manually using image processing programs to yield 3D image and coordinate value, systematic and random errors should be validated. We evaluated the accuracy and reliability of length measurement on CT with OsiriX software. 3D-CT scans were made of 14 frozen pig knees with five transosseous holes in the metaphyseal portion of femur. The lengths between tunnel orifices were measured using Mitutoyo Digimatic digital calipers to establish the gold standard, and with the OsiriX program in 3D multi-planar reformatting mode for comparison. All measurements were recorded by a principal (replicate 1, trial 1) and a secondary observer (replicate 2, trial 1) and were repeated once by each observer (trial 2). The mean differences between OsiriX and real measurements were less than 0.1 mm in both replicates, and maximum differences were less than 0.3 mm. There were no significant differences between the replicates and real measurements (p = 0.544 and 0.622 for replicates 1 and 2, respectively). The intraclass correlation coefficients (ICC) were very high between trials and between replicates (ICC = 0.998 and 0.999, respectively). For kinematic analysis of the knees, length measurements on 3D-CT using OsiriX program can be used as alternatives to real measurements with less than 0.3-mm accuracy and very high reliability.
      datePublished:2012-01-20T00:00:00Z
      dateModified:2012-01-20T00:00:00Z
      pageStart:486
      pageEnd:491
      sameAs:https://doi.org/10.1007/s10278-012-9458-6
      keywords:
         Computed tomography
         Accuracy
         Reliability
         Length
         OsiriX
         Imaging / Radiology
      image:
      isPartOf:
         name:Journal of Digital Imaging
         issn:
            1618-727X
            0897-1889
         volumeNumber:25
         type:
            Periodical
            PublicationVolume
      publisher:
         name:Springer-Verlag
         logo:
            url:https://www.springernature.com/app-sn/public/images/logo-springernature.png
            type:ImageObject
         type:Organization
      author:
            name:Gihyeon Kim
            affiliation:
                  name:Chung-Ang University
                  address:
                     name:Department of Radiology, College of Medicine, Chung-Ang University, Seoul, South Korea
                     type:PostalAddress
                  type:Organization
            type:Person
            name:Ho-Joong Jung
            affiliation:
                  name:Chung-Ang University
                  address:
                     name:Department of Orthopedic Surgery, College of Medicine, Chung-Ang University, Dongjak-ku, South Korea
                     type:PostalAddress
                  type:Organization
            email:[email protected]
            type:Person
            name:Han-Jun Lee
            affiliation:
                  name:Chung-Ang University
                  address:
                     name:Department of Orthopedic Surgery, College of Medicine, Chung-Ang University, Dongjak-ku, South Korea
                     type:PostalAddress
                  type:Organization
            type:Person
            name:Jae-Sung Lee
            affiliation:
                  name:Chung-Ang University
                  address:
                     name:Department of Orthopedic Surgery, College of Medicine, Chung-Ang University, Dongjak-ku, South Korea
                     type:PostalAddress
                  type:Organization
            type:Person
            name:Seungbum Koo
            affiliation:
                  name:Chung-Ang University
                  address:
                     name:School of Mechanical Engineering, Chung-Ang University, Seoul, South Korea
                     type:PostalAddress
                  type:Organization
            type:Person
            name:Seung-Hwan Chang
            affiliation:
                  name:Chung-Ang University
                  address:
                     name:School of Mechanical Engineering, Chung-Ang University, Seoul, South Korea
                     type:PostalAddress
                  type:Organization
            type:Person
      isAccessibleForFree:
      hasPart:
         isAccessibleForFree:
         cssSelector:.main-content
         type:WebPageElement
["Periodical","PublicationVolume"]:
      name:Journal of Digital Imaging
      issn:
         1618-727X
         0897-1889
      volumeNumber:25
Organization:
      name:Springer-Verlag
      logo:
         url:https://www.springernature.com/app-sn/public/images/logo-springernature.png
         type:ImageObject
      name:Chung-Ang University
      address:
         name:Department of Radiology, College of Medicine, Chung-Ang University, Seoul, South Korea
         type:PostalAddress
      name:Chung-Ang University
      address:
         name:Department of Orthopedic Surgery, College of Medicine, Chung-Ang University, Dongjak-ku, South Korea
         type:PostalAddress
      name:Chung-Ang University
      address:
         name:Department of Orthopedic Surgery, College of Medicine, Chung-Ang University, Dongjak-ku, South Korea
         type:PostalAddress
      name:Chung-Ang University
      address:
         name:Department of Orthopedic Surgery, College of Medicine, Chung-Ang University, Dongjak-ku, South Korea
         type:PostalAddress
      name:Chung-Ang University
      address:
         name:School of Mechanical Engineering, Chung-Ang University, Seoul, South Korea
         type:PostalAddress
      name:Chung-Ang University
      address:
         name:School of Mechanical Engineering, Chung-Ang University, Seoul, South Korea
         type:PostalAddress
ImageObject:
      url:https://www.springernature.com/app-sn/public/images/logo-springernature.png
Person:
      name:Gihyeon Kim
      affiliation:
            name:Chung-Ang University
            address:
               name:Department of Radiology, College of Medicine, Chung-Ang University, Seoul, South Korea
               type:PostalAddress
            type:Organization
      name:Ho-Joong Jung
      affiliation:
            name:Chung-Ang University
            address:
               name:Department of Orthopedic Surgery, College of Medicine, Chung-Ang University, Dongjak-ku, South Korea
               type:PostalAddress
            type:Organization
      email:[email protected]
      name:Han-Jun Lee
      affiliation:
            name:Chung-Ang University
            address:
               name:Department of Orthopedic Surgery, College of Medicine, Chung-Ang University, Dongjak-ku, South Korea
               type:PostalAddress
            type:Organization
      name:Jae-Sung Lee
      affiliation:
            name:Chung-Ang University
            address:
               name:Department of Orthopedic Surgery, College of Medicine, Chung-Ang University, Dongjak-ku, South Korea
               type:PostalAddress
            type:Organization
      name:Seungbum Koo
      affiliation:
            name:Chung-Ang University
            address:
               name:School of Mechanical Engineering, Chung-Ang University, Seoul, South Korea
               type:PostalAddress
            type:Organization
      name:Seung-Hwan Chang
      affiliation:
            name:Chung-Ang University
            address:
               name:School of Mechanical Engineering, Chung-Ang University, Seoul, South Korea
               type:PostalAddress
            type:Organization
PostalAddress:
      name:Department of Radiology, College of Medicine, Chung-Ang University, Seoul, South Korea
      name:Department of Orthopedic Surgery, College of Medicine, Chung-Ang University, Dongjak-ku, South Korea
      name:Department of Orthopedic Surgery, College of Medicine, Chung-Ang University, Dongjak-ku, South Korea
      name:Department of Orthopedic Surgery, College of Medicine, Chung-Ang University, Dongjak-ku, South Korea
      name:School of Mechanical Engineering, Chung-Ang University, Seoul, South Korea
      name:School of Mechanical Engineering, Chung-Ang University, Seoul, South Korea
WebPageElement:
      isAccessibleForFree:
      cssSelector:.main-content

External Links {🔗}(86)

Analytics and Tracking {📊}

  • Google Tag Manager

Libraries {📚}

  • Clipboard.js
  • Prism.js

CDN Services {📦}

  • Crossref

4.83s.